1. Introduction

The Electric Bill Calculator is a generic electricity billing tool that computes itemized bills for residential and commercial low-voltage customers. It supports tiered energy rates with a configurable tier limit basis, net billing for exported energy, fuel adjustments with a selectable basis (gross or net), demand charges with shortfall billing, ratchets, power factor penalties, minimum kWh consumption charges, post-tax electricity surcharges, interest on arrears computed from an entered balance and per-cycle interest rate, minimum bill enforcement, and configurable tax rates. The tool is tariff-agnostic — all rates and thresholds are user-defined inputs, making it applicable to any utility jurisdiction.

This calculator produces estimates based on user-supplied rate inputs. Actual utility bills may include additional charges, riders, adjustments, or rounding rules not modeled here. Always compare results against the utility's published tariff schedule and actual bill for verification.

1.1 Scope

The tool provides two independent calculators in a four-panel layout:

  • Residential: Three-tier energy billing with a selectable tier limit basis (per billing cycle or per month), fuel adjustment with selectable basis (gross or net), fixed service charge, net billing export credits, minimum bill enforcement, interest on arrears (post-tax), and tax.
  • Commercial: Flat or three-tier energy billing, fuel adjustment with selectable basis (gross or net), kVA demand charges with separate demand shortfall billing, minimum billable demand, demand ratchets, power factor penalties, minimum kWh consumption charge with demand suppression, post-tax electricity surcharge, fixed service charge, net billing export credits, minimum bill enforcement, interest on arrears (post-tax), and tax.

The two calculators are fully independent. Both support billing cycles of 1 to 4 months.

2. Residential Calculator

2.1 Input parameters

Field Units / options Description
Billing cycle 1–4 months Number of months covered by this bill. How this affects tier limits and fixed charges depends on the tier limit basis selection.
Units used kWh Total energy drawn from the grid during the billing period. Always entered as the total for the full billing period, never a monthly figure.
Units exported — / YES, kWh Its own Export section, below Consumption. The left field is a dropdown, "—" by default, with the kWh field beside it greyed out. Choose YES when the customer exports energy to the grid (e.g., from rooftop solar): the kWh field becomes editable and the export credit rate row appears. Enter the total exported over the billing period. It is used for the net billing credit and, when selected, the net fuel adjustment. While the dropdown is "—", exports are ignored even if the greyed-out field holds a value. Files saved before this dropdown existed switch it to YES automatically if they carry exported units.
Export credit rate $/kWh Per-kWh credit for exported energy under net billing. Offsets the bill after all charges are summed, before minimum bill enforcement. Shown only when Units exported is set to YES.
Tier limit basis Per billing cycle / Per month Controls whether the tier kWh limits and fixed charges are interpreted as per-cycle values (used as-is regardless of billing length) or per-month values (multiplied by billing cycle months). Use Per billing cycle when the utility tariff states tier boundaries as billing-period totals — the majority of Caribbean, Asian, and many other utilities. Use Per month (scaled) when the tariff defines tiers as monthly amounts that compound with the billing cycle length.
Tier 1 upper bound kWh Cumulative kWh threshold marking the top of Tier 1. All consumption from 0 to this value is billed at the Tier 1 rate. The left field is the kWh threshold; the right field is the Tier 1 rate in $/kWh.
Tier 2 upper bound kWh Cumulative kWh threshold marking the top of Tier 2. Consumption between the Tier 1 and Tier 2 thresholds is billed at the Tier 2 rate. Must be greater than the Tier 1 upper bound. The left field is the kWh threshold; the right field is the Tier 2 rate.
Tier 3 rate $/kWh Rate applied to all consumption above the Tier 2 upper bound. There is no upper boundary for Tier 3 — it absorbs all remaining kWh.
Service charge $ Fixed charge for the billing period. When tier limit basis is Per billing cycle, this value is used as-is. When Per month (scaled), this value is multiplied by the billing cycle months.
Fuel adjustment basis Gross imported kWh / Net (imported − exported) Determines the kWh quantity to which the fuel adjustment rate is applied. Select Gross imported kWh when the tariff charges the fuel rate against all consumed energy regardless of exports. Select Net (imported − exported) when the tariff applies the fuel rate only to net consumption; in net mode the quantity is clamped at zero when exports exceed imports (no negative fuel charge).
Fuel adjustment rate $/kWh Per-kWh surcharge applied to the quantity determined by the fuel adjustment basis. Represents a fuel cost pass-through or similar rider. Applied before the minimum bill check.
Minimum bill $ Floor value for the billing period. When tier limit basis is Per billing cycle, this value is used as-is. When Per month (scaled), it is multiplied by the billing cycle months. If the computed subtotal falls below this value, the subtotal is replaced by the minimum. Set to 0 to disable. Enforced pre-tax.
Tax rate % Applied as a percentage of the post-minimum subtotal. Represents VAT, sales tax, or other government levy.
Arrears / Interest rate $ / % Unpaid balance from a previous billing period and the per-cycle interest rate applied to it. The left field is the arrears amount in dollars; the right field is the interest rate in percent. Interest is computed as arrears × rate ÷ 100 and applied after tax. Both fields default to 0; set either to 0 to suppress the charge.

2.2 Tier limit basis

This is the most important input to understand when matching the calculator to a real utility tariff. Tier limits are always stated as cumulative upper bounds — the total kWh from zero up to the boundary, not the size of the tier block. A Tier 1 bound of 400 kWh and a Tier 2 bound of 1,000 kWh means:

  • Tier 1: first 400 kWh
  • Tier 2: next 600 kWh (from 400 to 1,000)
  • Tier 3: everything above 1,000 kWh

The Per billing cycle setting means these thresholds apply to the billing period as a whole, regardless of whether the cycle is 1, 2, or 3 months. This is how most utilities that issue bi-monthly or quarterly bills define their tariffs — the tier thresholds apply to each bill period as-is, without scaling.

The Per month (scaled) setting means the thresholds are monthly reference values that are multiplied by billing cycle length. A 200 kWh/month threshold on a 2-month cycle becomes an effective 400 kWh billing-period boundary. This matches tariffs from utilities that define monthly rates but issue multi-month bills (common in some US utilities).

The service charge and minimum bill follow the same basis rule: per-cycle values are used as-is; per-month values are multiplied by the number of months.

2.3 Algorithm

The residential billing algorithm executes in this order:

  1. Determine effective tier boundaries: If basis is Per month, multiply raw Tier 1 and Tier 2 limits by billing months. If basis is Per billing cycle, use raw limits unchanged.
  2. Allocate imported kWh across tiers: Tier 1 absorbs consumption from 0 to the Tier 1 boundary. Tier 2 absorbs from the Tier 1 boundary to the Tier 2 boundary. Tier 3 absorbs all remaining kWh above the Tier 2 boundary.
  3. Compute energy charge: Each tier's kWh allocation × its rate. Sum the three amounts.
  4. Compute fuel adjustment: Fuel kWh × fuel adjustment rate, where fuel kWh = imported for gross basis or max(0, imported − exported) for net basis.
  5. Compute service charge: Per-cycle basis: use the entered value as-is. Per-month basis: service charge × billing months.
  6. Compute export credit: Exported kWh × export credit rate (zero while the Export dropdown is "—").
  7. Compute pre-minimum subtotal: Energy + fuel + service − export credit. This value is displayed separately when a minimum bill override is active.
  8. Enforce minimum bill: If the pre-minimum subtotal is below the minimum bill value (after any scaling), replace it with the minimum. A note is displayed when this override fires.
  9. Apply tax: Subtotal × (tax rate / 100).
  10. Compute interest on arrears: Arrears × (interest rate ÷ 100). Applied once per cycle, outside the tax base. The row is hidden when the computed amount is zero.
  11. Compute total: Subtotal + tax + interest on arrears.
  12. Compute effective blended rate: Total ÷ imported kWh.

2.4 Output

The Residential Output panel displays an itemized bill with three columns: line item, quantity, and amount ($). Tier energy rows show kWh consumed in each tier. The total energy charge row shows total imported kWh and total energy amount. Service charge quantity reflects the billing basis (e.g., "2-month cycle" or "2 months"). The fuel adjustment quantity reflects the basis in use — the gross imported kWh value, or the clamped net kWh value. If the minimum bill was applied, a pre-minimum subtotal row appears above the subtotal row showing what the subtotal would have been without the override. The interest on arrears row appears below the tax row when non-zero, with the quantity column showing the arrears × rate% context (e.g., $500.00 × 1.50%) and the amount column showing the computed interest. The total bill amount is highlighted for visibility. The effective blended rate row appears below the total. A collapsible Calculation assumptions section lists the active modeling choices.

2.5 Worked example — tiered residential bill

A 2-month residential bill using per-cycle tier limits. Rates and structure representative of a Caribbean utility tariff:

Input Value
Billing cycle 2 months
Tier limit basis Per billing cycle
Tier 1 upper bound / rate 400 kWh / $0.26
Tier 2 upper bound / rate 1,000 kWh / $0.32
Tier 3 rate $0.37
Service charge $6.00
Tax rate 12.5% (VAT)

For 4,259 kWh imported: Tier 1 = 400 kWh × $0.26 = $104.00; Tier 2 = 600 kWh × $0.32 = $192.00; Tier 3 = 3,259 kWh × $0.37 = $1,205.83; Energy total = $1,501.83; Service charge = $6.00; Sub-total = $1,507.83; VAT 12.5% = $188.48; Total = $1,696.31.

3. Commercial Calculator

3.1 Input parameters

Field Units / options Description
Billing cycle 1–4 months Number of months covered by this bill.
Units used kWh Total energy drawn from the grid during the billing period, as read from the meter (after applying any meter multiplier). Always entered as the billing-period total.
Min. consumption threshold — / YES, kWh Some tariffs require customers to be billed for a minimum quantity of kWh regardless of actual consumption. The left field is a dropdown, "—" by default, with the kWh field beside it greyed out. Choose YES to enable the kWh field and show the min. kWh consumption rate row. When units used falls below this threshold, the minimum consumption charge is applied in place of the normal energy charge, and all demand charges (measured demand, shortfall) are suppressed. While the dropdown is "—", the override never applies. Files saved before this dropdown existed switch it to YES automatically if they carry a threshold.
Min. kWh consumption rate $/kWh Rate applied to the minimum consumption threshold when the override is active: the minimum consumption charge is threshold × rate (e.g., 5,000 kWh × $0.61 = $3,050). Shown only when Min. consumption threshold is set to YES; used only when units used < threshold.
Units exported — / YES, kWh Its own Export section, below Consumption. Same as residential: the kWh field is greyed out until the dropdown is set to YES, and exports are ignored while it is "—".
Export credit rate $/kWh Same as residential. Shown only when Units exported is set to YES.
Rate structure Flat / Tiered Selects between a single flat $/kWh rate or a three-tier structure. Flat shows the flat energy rate row. Tiered replaces it with the tier limit basis and Tier 1–3 rows, inside the same Energy rate section.
Flat energy rate $/kWh Single rate applied to all imported kWh. Visible only when rate structure is Flat.
Tier limit basis Per billing cycle / Per month Same as residential. Visible only when rate structure is Tiered. Also governs the service charge and minimum bill scaling.
Tier 1–2 upper bounds and rates kWh, $/kWh Same tiered logic as residential. Visible only when rate structure is Tiered.
Tier 3 rate $/kWh Rate applied to all consumption above the Tier 2 upper bound.
Measured demand Value, kVA / kW Peak demand recorded during the billing period — typically the highest 15-minute or 30-minute average interval reading as registered by the utility meter. Set to 0 if the tariff has no demand charge. The dropdown beside the value sets how the tariff measures demand: kVA (default) for tariffs such as T&TEC's, or kW for tariffs common in North America. All demand inputs, the demand charge rate and the output follow this unit. The power factor inputs appear only when kW is selected, because a kVA reading already rises as power factor falls.
Demand shortfall kVA or kW The gap between the measured demand and a contracted or reserve capacity threshold — for example, when a tariff requires customers to maintain a minimum reserved capacity (commonly expressed as a percentage of a contracted kVA) and the measured demand falls short of that minimum. The shortfall kVA is billed at the same demand charge rate as the measured demand and appears as a separate line item. Set to 0 if not applicable.
Demand charge rate $/kVA or $/kW Charge per unit of demand, applied to both the billed demand and the demand shortfall.
Demand floors — None (default) or Min. demand & ratchet. Selecting Min. demand & ratchet shows the two rows below; with None they are hidden and ignored. Files saved before this option existed switch it on automatically if they carry a minimum demand or an active ratchet.
Minimum billable demand kVA or kW A contractual demand floor that replaces the measured demand reading when the measured value falls below it. The utility bills max(measured demand, minimum billable demand) as a single figure. This is distinct from a demand shortfall: minimum billable demand substitutes for the measured reading, whereas a shortfall is an additive charge on top of it. Use this field for tariffs that specify a floor demand (e.g., "minimum 50 kVA billed"). Set to 0 to disable. Shown only when Demand floors is set to Min. demand & ratchet.
Demand ratchet %, kVA or kW Shown only when Demand floors is set to Min. demand & ratchet. Left field: ratchet percentage (e.g., 80). Right field: historical peak demand from the ratchet window (typically the highest demand in the preceding 11 months). Ratcheted demand = percentage × historical peak ÷ 100. If either input is 0, the ratchet is inactive.
Measured power factor 0–1 The customer's power factor for the billing period. Must be greater than 0 and no greater than 1. A warning is shown if PF = 0 and a threshold is set. Shown only when measured demand is in kW.
PF threshold 0–1 The tariff's minimum acceptable power factor. When the measured PF falls below this value, the measured kW is scaled up by threshold ÷ PF before it is compared with any demand floors. Shown only when measured demand is in kW. The adjustment does not apply to the demand shortfall, and is suppressed when the minimum kWh consumption override is active.
Service charge $ Fixed charge for the billing period. Scaled the same way as the residential service charge, per the tier limit basis setting.
Fuel adjustment basis Gross imported kWh / Net (imported − exported) Same semantics as residential. Determines whether the fuel rate is applied to gross imported kWh or to net imported kWh (imported − exported, clamped at zero).
Fuel adjustment rate $/kWh Per-kWh surcharge applied to the fuel kWh quantity determined by the basis setting.
Minimum bill, tax Various Same as residential.
Electricity surcharge $/kWh A flat per-kWh charge applied after tax. Some tariffs levy a separate surcharge outside the VAT base — this field models that line item. Applied to gross imported kWh. Set to 0 if not applicable.
Arrears / Interest rate $ / % Unpaid balance from a previous billing period and the per-cycle interest rate applied to it. The left field is the arrears amount in dollars; the right field is the interest rate in percent. Interest is computed as arrears × rate ÷ 100 and applied after tax (outside the VAT base). Both fields default to 0; set either to 0 to suppress the charge.

3.2 Algorithm

  1. Check minimum kWh consumption override: If the Min. consumption threshold dropdown is YES and units used < threshold (threshold and rate both non-zero), the override is active. The energy charge is replaced by threshold × min. kWh consumption rate, and all demand charges — measured demand, shortfall, and power factor penalty — are suppressed to zero.
  2. Compute energy charge: If the minimum kWh override is active, use the min. kWh consumption rate directly. Otherwise: if flat rate, energy charge = units used × flat rate. If tiered, determine effective boundaries using the tier limit basis rule, allocate kWh across three tiers, sum tier amounts.
  3. Compute fuel adjustment: Fuel kWh × fuel adjustment rate, where fuel kWh = imported for gross basis or max(0, imported − exported) for net basis.
  4. Determine billed demand (if override inactive):
    • If Demand floors is None, minimum billable demand and ratcheted demand are both 0
    • Ratcheted demand = ratchet % × historical peak ÷ 100 (0 if either input is 0)
    • Billed demand = max(measured demand, minimum billable demand, ratcheted demand)
  5. Compute demand charge: Billed demand × demand charge rate.
  6. Compute demand shortfall charge: Demand shortfall × demand charge rate. This is a separate additive line item, not a substitute for the measured demand charge.
  7. Identify demand override source: If billed demand exceeds measured demand, the output note identifies whether the ratchet or the minimum demand floor was the controlling factor.
  8. Compute power factor adjustment (kW demand only, if override inactive): If 0 < measured PF < PF threshold: PF-adjusted demand = max(measured kW × threshold ÷ measured PF, minimum billable demand, ratcheted demand), and PF adjustment = (PF-adjusted demand − billed demand) × demand charge rate. When a demand floor already exceeds the adjusted kW, the adjustment is zero. If PF = 0 with a threshold set, a warning is displayed and no adjustment is calculated. With kVA demand this step is skipped.
  9. Compute service charge: Per-cycle basis: entered value as-is. Per-month basis: × billing months.
  10. Compute export credit: Exported kWh × export credit rate (zero while the Export dropdown is "—").
  11. Compute pre-minimum subtotal: Energy + fuel + demand + shortfall + PF penalty + service − export credit.
  12. Enforce minimum bill, apply tax: Same as residential.
  13. Apply post-tax charges: Electricity surcharge (units used × surcharge rate) and interest on arrears (arrears × rate ÷ 100) are added after tax. These are outside the VAT base.
  14. Compute total: Subtotal + tax + surcharge + interest.
  15. Compute effective blended rate: Total ÷ units used.

3.3 Demand billing concepts

What is demand? Demand measures the power drawn from the supply at a point in time — as apparent power (kVA) or real power (kW), depending on the tariff. While energy (kWh) is the total volume consumed over a billing period, demand is the peak load the utility must be prepared to serve. Utilities record demand as the highest average kVA or kW over a defined interval (typically 15 or 30 minutes). Demand charges recover the utility's fixed costs of maintaining generation, transmission, and distribution capacity to meet peak requirements regardless of total kWh consumed. Billing on kVA rather than kW inherently accounts for power factor — a customer with a low power factor draws more apparent power for the same real power, and is therefore billed more without requiring a separate penalty mechanism.

What is a demand shortfall? Some tariffs require commercial customers to contract for a reserved capacity — a guaranteed maximum kVA the utility will have available at all times. A portion of that reserved capacity (commonly 75%) is the minimum the customer is expected to utilize each billing period. If measured demand falls below this minimum, the gap (shortfall kVA) is charged at the same demand rate as a separate line item on top of the measured demand charge. Unlike minimum billable demand — which substitutes for the measured reading — a shortfall charge is additive: the customer pays for both what they actually used and the unused portion of their reserved capacity.

What is minimum billable demand? A contractual demand floor that replaces the measured reading when the measured value is lower. The utility bills max(measured demand, minimum billable demand) as a single figure. This is different from a demand shortfall: minimum billable demand is a substitution on the measured value, while a shortfall is an additional charge for unused reserved capacity. Use this field for tariffs that specify an absolute floor (e.g., "minimum 50 kVA billed regardless of actual demand"). Set to 0 to disable.

What is a demand ratchet? A ratchet prevents billed demand from falling below a percentage of the customer's historical peak. For example, an 80% ratchet with a 100 kVA historical peak means the customer is always billed for at least 80 kVA, even if current measured demand is 50 kVA. Ratchets ensure the utility recovers capacity costs from customers who have required high capacity in recent history and are a strong incentive for peak demand management.

What is a minimum kWh consumption charge? Some tariffs specify that customers must be billed for a minimum quantity of energy regardless of actual consumption. When units used falls below the minimum threshold, the normal energy charge is replaced by the minimum consumption charge (the minimum kWh × its rate), and all demand charges are suppressed. The utility treats low-consumption billing periods as fixed-charge events without applying demand penalties.

What is a power factor penalty? Power factor (PF) is the ratio of real power (kW) to apparent power (kVA). When a tariff bills on kVA demand, low PF is already penalized through the higher kVA reading, so the calculator applies no separate adjustment and hides the power factor inputs. Tariffs that bill on kW demand often scale the measured kW up when PF falls below a threshold (commonly 0.90 or 0.95): billed kW = measured kW × threshold ÷ actual PF. The calculator compares this adjusted kW with any demand floors and shows the extra demand charge as the power factor adjustment. The adjustment does not apply to the demand shortfall, and is suppressed when the minimum kWh consumption override is active.

3.4 Output

The Commercial Output panel displays an itemized bill with three columns: line item, quantity, and amount ($). Energy charge, fuel adjustment, billed demand charge, demand shortfall charge, power factor adjustment, service charge, and export credit appear as separate line items. The fuel adjustment quantity reflects the active basis — gross imported kWh or clamped net kWh. The demand shortfall row is hidden when shortfall is zero, and the power factor adjustment row is shown only when measured demand is in kW. If billed demand exceeds measured demand, a note below the table identifies the controlling factor (ratchet or minimum demand floor). If the minimum kWh consumption override is active, a note identifies this and confirms demand suppression. The electricity surcharge and interest on arrears rows appear after the tax row when non-zero, reflecting their post-tax position. The interest on arrears quantity column shows the arrears × rate% context (e.g., $10,000.00 × 1.50%) and the amount column shows the computed interest. The total bill amount is highlighted for visibility. If the minimum bill was applied, a pre-minimum subtotal row is shown.

4. Validation and warnings

The calculator performs lightweight real-time validation and displays warnings below the relevant input sections. No calculation is blocked — the engine always runs with the entered values — but the following conditions are flagged:

  • Tier ordering: If the Tier 2 upper bound is less than or equal to the Tier 1 upper bound, a warning is shown. This would produce a zero-width or negative Tier 2 block and is almost always a data entry error.
  • Export exceeds import: If exported kWh is greater than imported kWh (and imported > 0), a warning advises verifying net billing eligibility. Some tariffs cap credits or disallow negative energy subtotals. In net fuel basis mode this condition also results in fuel kWh clamping to zero, preventing a negative fuel adjustment.
  • Power factor = 0: If PF is entered as 0 with a non-zero threshold and a non-zero demand charge, a warning is shown and no penalty is calculated. A PF of exactly 0 is not physically meaningful in this context.
  • Power factor out of range: If PF is entered outside the 0–1 range, a warning is shown.

5. Net billing vs net metering

This calculator implements net billing, not net metering. Under net billing, imported and exported kWh are valued separately: imports are billed at the full retail tariff, exports earn a credit at the (typically lower) export credit rate, and the credit offsets the bill after all charges are summed. Under net metering, the meter runs backward and kWh are netted at the retail rate before billing.

Net billing is the more common framework for modern solar interconnection agreements. To approximate net metering, set the export credit rate equal to the effective retail rate and set the minimum bill to 0.

The export credit in this calculator offsets all charge types including demand and fixed charges. Some tariffs restrict credits to the energy charge only. The Calculation assumptions section in each output panel states the active assumption.

The fuel adjustment basis selector provides additional flexibility for net-metered customers: selecting Net (imported − exported) applies the fuel adjustment rate only to the net kWh consumed, matching tariffs where fuel passthrough is a function of net rather than gross consumption. In gross basis mode the fuel rate applies to all imported kWh regardless of exports.

6. Billing cycle and scaling

Billing cycle length interacts with the Tier limit basis selection to determine which values are scaled:

Value Per billing cycle basis Per month basis
Tier kWh limits Used as-is Multiplied by billing months
Service charge Used as-is Multiplied by billing months
Minimum bill Used as-is Multiplied by billing months
Imported / exported kWh Always the billing-period total — never scaled
Measured demand (kVA) Peak value — never scaled
Demand shortfall (kVA) Entered value — never scaled
Fuel adjustment Applied to fuel kWh (gross or net per basis selector) — never scaled separately by billing months
Electricity surcharge Applied to gross imported kWh after tax — never scaled separately
Interest on arrears Computed as arrears × rate ÷ 100, applied once per cycle — never scaled by billing months. The entered rate is the per-cycle rate, not an annualized (APR) figure.

7. Calculation assumptions

Each output panel includes a collapsible Calculation assumptions section. This lists the modeling choices that are baked into the current calculation — items that may differ from some utility tariffs but cannot be made configurable without significantly increasing complexity. Key assumptions:

  • Fuel adjustment is applied to the kWh quantity determined by the fuel adjustment basis selector (gross or net). In net mode the quantity is clamped at zero when exports exceed imports.
  • Tax is applied to the post-minimum subtotal (not to individual line items).
  • Export credit offsets all charge types (energy, demand, fixed charges).
  • Minimum bill is enforced pre-tax.
  • Tier limits are cumulative upper bounds, not per-tier block sizes.
  • Demand charge is a single billing-period value and is not scaled by billing months.
  • Demand shortfall is charged at the same rate as measured demand and is additive, not a substitution.
  • Power factor penalty is applied to the combined measured demand charge and shortfall charge.
  • Electricity surcharge is applied after tax (outside the VAT base).
  • Interest on arrears is computed as arrears × rate ÷ 100, applied once per billing cycle, outside the VAT base. The interest rate is entered as a per-cycle figure, not an annualized rate.
  • When the minimum kWh consumption override is active, all demand charges and power factor penalty are suppressed.

The assumptions text updates dynamically to reflect the active basis and rates. For example, when the fuel rate is zero the note indicates this, and when no export credit applies it is noted explicitly.

8. Limitations

  • Time-of-use (TOU) rates, seasonal rate variations, and tiered demand charges are not modeled.
  • The power factor penalty uses the (threshold/PF − 1) × demand charge method only. This is applied to the combined measured demand and shortfall charge.
  • The demand ratchet accepts a single historical peak value. It does not track a rolling history across sessions.
  • A single tax rate is applied to the final subtotal. Per-line-item taxability (e.g., tax on energy but not demand) is not modeled.
  • Interest on arrears uses simple interest (arrears × rate ÷ 100) applied once per cycle. Compounding, accrued daily interest, and rolling balance tracking across billing periods are not modeled. The entered rate must be the per-cycle interest rate; if a utility states an annualized rate (APR), the user must scale it to a per-cycle equivalent before entry.
  • Only two rate bases are supported for fuel adjustment: gross imported kWh or net (imported − exported, clamped at zero). Tariffs that apply different fuel rates per tier, or per time-of-use period, are not modeled.