kVATools.io ❯ CT Cabinet
| | |
Inputs — Application & System
| Application | Standard | |
| Application Type | ||
| CT Construction | ||
| Rated Secondary | ||
| System | System Voltage | |
| Phase Configuration | ||
| Frequency | ||
| Currents | Max Continuous Load | |
| Load Basis | ||
| Max Symmetrical Fault | | |
| Fault Duration (s) | ||
| Lead-Length Fault Basis | ||
| Scheme | X/R at Fault Point | |
| Min Fault (optional) | | |
| Protection Type |
Lead-Length Fault Basis sets the lead-loop resistance: a phase-to-ground fault returns through the neutral lead (2 × one-way run, per IEEE C37.110); a balanced 3Ø fault sums to zero in the neutral (1 × one-way run). Ø-G is the conservative default. Fault Duration is the total time the fault can flow; the 1 s thermal rating to specify is If × √t (C57.13 §6.6.2). Relay Ktd (IEC only) is the transient dimensioning factor from the relay manufacturer; blank sizes class P for symmetrical current, as 61869-2 defines it.
Inputs — Burden & Leads
| Connected Devices | Relay Technology | |
| Relay Burden | | |
| Other Devices (VA) | ||
| Test Switch / Blocks (Ω) | ||
| Meter Burden | | |
| Secondary Leads | Conductor Size | |
| One-way Run Length | | |
| Lead Material | ||
| Lead Temperature (°C) | ||
| CT Winding | Rct at 75 °C (Ω, optional) |
Relay Technology prefills typical burdens (microprocessor ≈0.02 Ω, solid-state ≈0.10 Ω, electromechanical ≈1.0 Ω); override the value for the actual device. Leave Rct blank to use a typical-by-ratio estimate (≈2.5 mΩ per secondary turn for 5 A windings, ≈7.5 mΩ per turn for 1 A). Results using the estimate are labelled accordingly; use the test-report value when available.
Inputs — Environment & Class Targets
| Environment | Average Ambient (°C) | |
| Altitude (m) | ||
| Rating Factor (RF) | ||
| Class Targets | Metering Class | |
| Protection Class | ||
| Options | Multi-ratio (MR) CT |
ANSI RF is rated at 30 °C average ambient per IEEE C57.13 §6.5; above 30 °C the effective factor is derated (Figure 1 basis). IEC has no RF concept and instead uses extended current ratings of 120/150/200% per 61869-2 §5.203.
Output — Recommended CT
| Ratio | Load | Fault ×In | Verdict | Rationale |
|---|---|---|---|---|
| — | ||||
Output — Burden Analysis
| Quantity | Value | Units |
|---|---|---|
| Lead Loop Resistance | — | Ω |
| Device Burden (Σ) | — | Ω |
| Total Connected Burden | — | Ω |
| Total Burden at Rated Current | — | VA |
| Required Standard Burden | — | — |
| Burden Verdict | — | — |
| Secondary | Total Burden | VA at Rated | Lead Share |
|---|---|---|---|
| — | |||
Output — Saturation & Accuracy
| Quantity | Value | Units |
|---|---|---|
| Protection — IEEE C37.110 / IEC 61869-2 | ||
| Secondary Fault Current Is | — | A |
| Rct Used | — | Ω |
| Vs Required (symmetrical) | — | V |
| Vs Required × (1 + X/R) | — | V |
| Required Accuracy Class | — | — |
| Saturation Margin | — | % |
| Metering — C57.13 §5 / 61869-2 §5.6.201 | ||
| Secondary Current at Load | — | A |
| Load Position | — | % rated |
| Specify Metering CT As | — | — |
| Accuracy Range Verdict | — | — |
Output — Ratings & MR Taps
| Quantity | Value | Units |
|---|---|---|
| Effective RF at Ambient | — | — |
| Continuous Capability | — | A |
| Specify Ith (1 s) ≥ | — | kA |
| Dynamic / Mechanical Rating | — | kA pk |
| Insulation Class / BIL | — | — |